Test 2021-01-04-8-4 (AASHTO T315-16) Summary

The test has been saved successfully.
Project Information
Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date1/4/2021 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/13/2021
Sample typeVerification A brief description of the sampleCOC Sample
The quantity of what the sample constitutes1 of 1 From where was the sample collectedManufacturer
First name of sampler or witnessed byNOT Last name of sampler or witnessed byPROVIDED
Title of sampler Laboratory sample identification21-002
The fabricator/manufacturer/facility nameHolly Frontier Glendale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number
Time of sample09:30 HMA SupplierNot set
Asphalt Binder SupplierNot set MultigradeNot set
JMF Verification ID
Test Details
DIME Sample ID: 2021-01-04-8
DIME Test ID: 2021-01-04-8-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-01-22
Test Results

Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 01/21/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.145 kPa
Phase Angle (δ) (for the 10 cycles): 88.1 degree
Complex Modulus (G*) (for the 10 measurements): 1.211 kPa
Test Temperature: 70.0 C
Dynamic Shear, G*/sin(δ): 1.21 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Std Specs ORIG

Test was verified on 01/22/2021