Summary for Test 2019-05-13-16-3
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 214175 DEA: 030H4804 EFIS: 0315000198 |
---|---|
DIST-CO-RTE-PM | 03-SAC-99-0.1/1.6,11.8/21.6 |
Award Date | 08/20/2019 |
Closeout Date | 08/11/2023 |
Work Description | COLD PLANE AC PAVEMENT AND RHMA OVERLAY. |
Location Description | SACRAMENTO COUNTY IN AND NEAR GALT FROM DRY CREEK BRIDGE TO SIMMERHORN ROAD AND IN ELK GROVE AND SACRAMENTO FROM 0.9 MILE SOUTH OF ELK GROVE BOULEVARD TO MARTIN LUTHER KING JR BOULEVARD |
QA Service Level | 1 (Verified on 05/29/2019) |
Sample Information
Sample Taken Date | 05/13/2019 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2020 |
Sample type | Verification | A brief description of the sample | 3/4" HMA - A |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | J. | Last name of sampler or witnessed by | Kort (WITNESS) |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | JMF20-013 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | George Reed - Clements Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-03-0020::JACKSON VALLEY QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Hot Drop at the Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-05-13-16
DIME Test ID: 2019-05-13-16-3
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2021-01-21
Test Results
How many times will the test be run?: Once
Input Type: Calculated
Tester's full name: D-10 Lab Personnel
Date of test: 05/15/2019
Sand Equivalent: 70
General comments (publicly viewable) (Max 1000 characters): JMF20-013. Test date is an estimated guess, based on a completed CEM-3513 form from D-10.
Test was verified on 1/21/2021 ✔