Test 2021-01-06-4-2 (ASTM A970-15e1) Summary

Project Information
Project IdentifiersProject ID: 214937
DEA: 11288834
EFIS: 1117000088
DIST-CO-RTE-PM11-SD-11,125,905-various
Work DescriptionCONSTRUCT CONCRETE BRIDGE, PAVEMENT, BARRIER, AND INSTALL LIGHTING. HPLUL-6211(133) SR-125 SB to WB SR-905
Location DescriptionSAN DIEGO COUNTY IN AND NEAR SAN DIEGO AT ROUTE 11/125/905 SEPARATION
Sample Information
Sample Taken Date1/6/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/7/2021
Sample typeQuality Assurance A brief description of the sampleErico End Anchor Heads
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byNikku Last name of sampler or witnessed byTiongco
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameCMC Rebar Erico Transportation Laboratory (TL) NumberC
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)1066926 Head Manufacturer Lot Number(s)A1220
Rebar Size#14 Headed Bar Model NameLenton EL 43TD14 T2
Size of HeadFull Size - 9x Head Connection TypeThreaded
Head ShapeCircular Rebar ManufacturerCMC Rebar
Head ManufacturerErico Head FabricatorErico
Material Standard CodeASTM A706
Test Details
DIME Sample ID: 2021-01-06-4
DIME Test ID: 2021-01-06-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-01-11
Test Results

Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 01/08/2021
UTM: 400kip
Temperature:72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
112.2520826992564Head Pull Offfsaylor

General comments (publicly viewable) (Max 1000 characters): Head Pull Off
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 01/11/2021