Summary for Test 2021-01-06-4-1
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 214937 DEA: 11288834 EFIS: 1117000088 |
---|---|
DIST-CO-RTE-PM | 11-SD-11,125,905-various |
Award Date | 07/28/2020 |
Closeout Date | 03/05/2024 |
Work Description | CONSTRUCT CONCRETE BRIDGE, PAVEMENT, BARRIER, AND INSTALL LIGHTING. HPLUL-6211(133) SR-125 SB to WB SR-905 |
Location Description | SAN DIEGO COUNTY IN AND NEAR SAN DIEGO AT ROUTE 11/125/905 SEPARATION |
QA Service Level | 1 (Verified on 09/04/2020) |
Sample Information
Sample Taken Date | 01/06/2021 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/07/2021 |
Sample type | Quality Assurance | A brief description of the sample | Erico End Anchor Heads |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Nikku | Last name of sampler or witnessed by | Tiongco |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Rebar Erico | Transportation Laboratory (TL) Number | C |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 1066926 | Head Manufacturer Lot Number(s) | A1220 |
Rebar Size | #14 | Headed Bar Model Name | Lenton EL 43TD14 T2 |
Size of Head | Full Size - 9x | Head Connection Type | Threaded |
Head Shape | Circular | Rebar Manufacturer | CMC Rebar |
Head Manufacturer | Erico | Head Fabricator | Erico |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2021-01-06-4
DIME Test ID: 2021-01-06-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2021-01-11
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 01/08/2021
UTM: 400kip
Temperature: 72 f
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 2.25 | 207071 | 92031 | Head Pull Off | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Head Pull Off
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 1/11/2021 ✔