Test 2020-12-31-1-3 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 214937
DEA: 11288834
EFIS: 1117000088
DIST-CO-RTE-PM11-SD-11,125,905-various
Work DescriptionCONSTRUCT CONCRETE BRIDGE, PAVEMENT, BARRIER, AND INSTALL LIGHTING. HPLUL-6211(133) SR-125 SB to WB SR-905
Location DescriptionSAN DIEGO COUNTY IN AND NEAR SAN DIEGO AT ROUTE 11/125/905 SEPARATION
Sample Information
Sample Taken Date12/31/2020 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/7/2021
Sample typeQuality Assurance A brief description of the sampleHRC 500 510 Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byTiffany Last name of sampler or witnessed byClonls
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameHRC CMC Rebar Transportation Laboratory (TL) NumberC690865
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#14 Coupler ModelHRC 500-510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)74117089 74118343 Rebar Heat Number(s)1066925
Rebar Size 2
Test Details
DIME Sample ID: 2020-12-31-1
DIME Test ID: 2020-12-31-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-01-07
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 01/07/2021
UTM:2000kip
Temperature:72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 14/43mm102.2521137593944OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 01/07/2021