Summary for Test 2015-04-29-2-1

Test performed: CTM 521-November 2014

Project Information

Project IdentifiersProject ID: 209019
DEA: 071952U4
EFIS: 0700000201
DIST-CO-RTE-PM07-VEN-23,101-3.3/3.8,R0.1/R4.5
Award Date11/21/2013
Closeout Date06/25/2019
Work DescriptionWIDEN FREEWAY AND RAMPS AND RECONSTRUCT MEDIAN.
Location DescriptionVENTURA COUNTY IN THOUSAND OAKS ON ROUTE 101 FROM 0.6 MILE SOUTH OF WESTLAKE BOULEVARD OVERCROSSING TO 0.4 MILE NORTH OF MOORPARK ROAD UNDERCROSSING AND ON ROUTE 23 FROM ROUTE 101 TO 0.1 MILE NORTH OF HILLCREST DRIVE UNDERCROSSING
QA Service Level1 (Verified on 08/13/2013)

Sample Information

Sample Taken Date04/29/2015 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/05/2015
Sample typeVerification A brief description of the sample6x12
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byA Last name of sampler or witnessed byMAGHSOUDLOO
Title of samplerASR Telephone number of samplerUnknown
Laboratory sample identification876-20 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameJOB Transportation Laboratory (TL) Number106620
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierCONEJO BENT 3 INFILL WALL
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberS72500
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedNOT PROVIDED
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedNOT PROVIDED Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2015-04-29-2
DIME Test ID: 2015-04-29-2-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-05-13

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 05/13/2015
Average diameter of cylinder 1: 6 in
Average diameter of cylinder 2: 6 in
Maximum load on cylinder 1: 93360 lb
Maximum load on cylinder 2: 98510 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 14 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 3302.4 psi
Compressive strength of cylinder 2: 3484.6 psi
Compressive strength (to nearest 10 psi): 3390 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/13/2015