Summary for Test 2020-12-19-2-10

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 213970
DEA: 080K1214
EFIS: 0815000245
DIST-CO-RTE-PM08-SBD-15-12.5/14.8
Award Date12/23/2019
Closeout Date01/18/2022
Work DescriptionREPLACE PCC PAVEMENT WITH JPCP AND PRECAST JOINTED CONCRETE PAVEMENT.
Location DescriptionSAN BERNARDINO COUNTY IN FONTANA AND NEAR DEVORE FROM 0.3 MILE SOUTH OF SIERRA AVENUE UNDERCROSSING TO GLEN HELEN PARKWAY UNDERCROSSING
QA Service Level1 (Verified on 12/12/2019)

Sample Information

Sample Taken Date12/19/2020 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/22/2020
Sample typeVerification A brief description of the samplePSUE 1/2" RHMA-G-SP 0.5% LAS
The quantity of what the sample constitutes4 Bags Of Coldfeed Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byJulius Last name of sampler or witnessed byEsonwune
Title of sampler Telephone number of sampler
Laboratory sample identification0708G-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0027, 91-33-0073
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number326120 CORD SJR A detailed description of where the material sample was collectedVulcan Materials-Corona
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-12-19-2
DIME Test ID: 2020-12-19-2-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2020-12-31

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 12/27/2020
Bulk dry specific gravity: 2.601
Average uncompacted voids: 46.7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/31/2020