Test 2020-08-13-23-6 (AASHTO T324-14) Summary

Project Information
Project IdentifiersProject ID: 214572
DEA: 034E62U4
EFIS: 0319000068
DIST-CO-RTE-PM03-ED-50-18.5/24.2
Work DescriptionCONSTRUCT UC, MED BARRIER, DRAINAGE SYSTEMS & HMA OVERLAY.
Location DescriptionEL DORADO COUNTY IN AND NEAR PLACERVILLE FROM MOSQUITO ROAD UNDERCROSSING TO SCHNELL SCHOOL ROAD UNDERCROSSING AND FROM 0.2 MILE WEST OF STILL MEADOW ROAD TO 0.2 MILE EAST OF CARSON ROAD
Sample Information
Sample Taken Date8/13/2020 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing8/14/2020
Sample typeVerification A brief description of the sample3/4 inch HMA - A
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byMike Last name of sampler or witnessed byO'Halloran (WITNESS)
Title of samplerTeichert Personnel Laboratory sample identificationJMF20-035
The fabricator/manufacturer/facility nameTeichert Aggregates - Grantline Plant Transportation Laboratory (TL) Numberc765906
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number JMF Verification ID JMF3513-2020-232
Test Details
DIME Sample ID: 2020-08-13-23
DIME Test ID: 2020-08-13-23-6
Testing Lab: CT D03 - North Region Materials Lab
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2020-12-30
Test Results

Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 08/27/2020
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average:no data
Impression at specified number of passes average:no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A):25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B):25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A):4.14 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B):6.99 mm
Stripping Inflection Point (Wheel A):25000
Stripping Inflection Point (Wheel B):25000
General comments (publicly viewable) (Max 1000 characters): JMF20-035.

Test was verified on 12/30/2020