Test 2020-12-02-3-4 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 210735
DEA: 071193U4
EFIS: 0713000007
DIST-CO-RTE-PM07-LA-10-37.2/42.4
Work DescriptionCONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location DescriptionIN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
Sample Information
Sample Taken Date12/2/2020 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/4/2020
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R15 No LAS
The quantity of what the sample constitutes3 Bags Coldfeed Agg., 2 Bags Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byCesar Last name of sampler or witnessed byOllarsaba
Title of sampler Laboratory sample identification0682A-20
The fabricator/manufacturer/facility nameAll American Asphalt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0005
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample
The plant number105973 A detailed description of where the material sample was collectedBelt Cut at All American Irwindale Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2020-12-02-3
DIME Test ID: 2020-12-02-3-4
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-12-29
Test Results

Input Type: Measured
Tester's full name: Friday Ofoegbu
Date of test: 12/05/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 988.9 grams
Mass of the pycnometer with water (B): 674.7 grams
Mass of the oven dried sample (before pycnometer) (A): 492.9 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 492.9 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.653
Bulk specific gravity (SSD Basis):2.691
Apparent specific gravity:2.758
Absorption:1.4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/29/2020