Test 2020-12-10-17-3 (AASHTO T315-16) Summary

Project Information
Project IdentifiersProject ID: 209520
DEA: 06470904
EFIS: 0600000973
COOP: 061529
DIST-CO-RTE-PM06-MAD-99-R7.5/15.1
Work DescriptionWIDEN FREEWAY FROM 4 LANES TO 6 LANES.
Location DescriptionMADERA COUNTY IN AND NEAR MADERA FROM AVENUE 12 OVERCROSSING TO 0.9 MILE NORTH OF AVENUE 17 OVERCROSSING
Sample Information
Sample Taken Date12/10/2020 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/18/2020
Sample typeAcceptance A brief description of the sampleAsphalt Binder used for HMA
The quantity of what the sample constitutes1 of 1 From where was the sample collectedOther
First name of sampler or witnessed byNot Last name of sampler or witnessed byProvided
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameVulcan Madera Plant Transportation Laboratory (TL) Numberc056312
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number9001
Time of sample HMA SupplierNot set
Asphalt Binder SupplierNot set MultigradeNot set
Multigrade TypeNot set HMA Design ID
Test Details
DIME Sample ID: 2020-12-10-17
DIME Test ID: 2020-12-10-17-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-12-23
Test Results

Phase: Original binder
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 12/23/2020
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.149 kPa
Phase Angle (δ) (for the 10 cycles): 89.5 degree
Complex Modulus (G*) (for the 10 measurements): 1.241 kPa
Test Temperature (Specimen 1): 70.0 C
Dynamic Shear, G*/sin(δ): 1.24 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications

Test was verified on 12/23/2020