Summary for Test 2020-12-01-16-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 215374 DEA: 060X2704 EFIS: 0618000048 |
---|---|
DIST-CO-RTE-PM | 06-FRE-5-37.2/48.8 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | PAVEMENT REHABILITATION |
Location Description | FROM 1.9 MILES NORTH OF THREE ROCKS ROAD UC TO 0.2 MILES SOUTH OF PANOCHE ROAD OC |
QA Service Level | 1 (Verified on 12/16/2020) |
Sample Information
Sample Taken Date | 12/01/2020 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/15/2020 |
Sample type | Per Request | A brief description of the sample | Soil |
The quantity of what the sample constitutes | 1 Bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | E | Last name of sampler or witnessed by | Easterling |
Title of sampler | Transportation Engineer | Telephone number of sampler | |
Laboratory sample identification | CR20200562 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Caltrans | Transportation Laboratory (TL) Number | C0X2704 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 06-FRE-5-PM 37.2/48.8 | |
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | 20-D-086 |
---|---|---|---|
The fabricator/manufacturer designation for the sample | corrosion testing | A detailed description of where the material sample was collected | East Side of I-5 at PM 44.48, At Surface at Outlet |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2020-12-01-16
DIME Test ID: 2020-12-01-16-1
Testing Lab: Wood
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-12-23
Test Results
The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Tim Steele
Date of test: 12/22/2020
Minimum soil resistance of the lab measurement: 360 Ohms
Soil sample temperature: 18 C
Soil box constant: 1
pH of soil: 6.61
Minimum soil resistance corrected to 15.5: 383.00 Ohm-cm
Minimum soil resistivity at 15.5: 383 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/23/2020 ✔