Test 2015-04-30-2-1 (ASTM C39-17a) Summary

Project Information
Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
Sample Information
Sample Taken Date4/30/2015 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/5/2015
Sample typeVerification A brief description of the sampleBike Path Span3 9 thru12
The quantity of what the sample constitutes45 From where was the sample collectedJob Site
First name of sampler or witnessed byBrandon Last name of sampler or witnessed byYoung
Title of samplerASR Laboratory sample identificationUnknown
The fabricator/manufacturer/facility nameCentral Concrete Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown
Material Information
Material TypeConcrete The concrete mix design numberD11C5E1
The truck number from where the sample was collected1227 The batch plant ticket number from where the sample was collected18012006
Concrete batch plantPerlta The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedNear W4R Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set
Test Details
DIME Sample ID: 2015-04-30-2
DIME Test ID: 2015-04-30-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-05-07
Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mike Mullins
Date of test: 05/07/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 5.99 in
Maximum load on cylinder 1: 91007 lb
Maximum load on cylinder 2: 81678 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.18 in^2
Compressive strength of cylinder 1: 3219.2 psi
Compressive strength of cylinder 2: 2898.4 psi
Compressive strength (to nearest 10 psi):3060 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 05/07/2015