Summary for Test 2020-11-30-16-1

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 215364
DEA: 07333204
EFIS: 0716000301
DIST-CO-RTE-PM07-LA-5-.8/.8
Award Date09/08/2021
Closeout Date03/01/2023
Work DescriptionINSTALL SOLAR PV POWERED LIGHTING SYSTEM.
Location DescriptionIN KERN COUNTY NEAR LEBEC AT VARIOUS LOCATIONS FROM OFF-RAMP OF NORTHBOUND REST AREA TO 0.1 MILE NORTH OF OFF-RAMP OF SOUTHBOUND REST AREA.
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date11/30/2020 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/04/2020
Sample typePer Request A brief description of the samplesoil
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byAdam Last name of sampler or witnessed byAvakian
Title of samplerGeotech Engineer Telephone number of sampler9162037625
Laboratory sample identificationCR20200558 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCaltrans Transportation Laboratory (TL) NumberC002434
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier06-KER-005 1.12 PM
Structure nameSolar Panel Project

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleHA-20-002
The fabricator/manufacturer designation for the sampleCorrosion testing A detailed description of where the material sample was collected0-2 feet depth
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2020-11-30-16
DIME Test ID: 2020-11-30-16-1
Testing Lab: Wood
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2020-12-22

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Calculated
Tester's full name: Sarah Mauri
Date of test: 12/16/2020
Minimum soil resistance of the lab measurement: 1850 Ohms
Soil sample temperature: 19.4 C
Soil box constant: 1
pH of soil: 7.44
Minimum soil resistance corrected to 15.5: 2030.00 Ohm-cm
Minimum soil resistivity at 15.5: 2030 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/22/2020