Summary for Test 2020-11-16-37-1
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/16/2020 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/14/2020 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | Washed Concrete Sand |
The quantity of what the sample constitutes | production stockpile. | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jon | Last name of sampler or witnessed by | Blumer |
Title of sampler | QA Technician | Telephone number of sampler | 530-749-1182 |
Laboratory sample identification | 20-APPF-0232 | Linked DIME Sample ID | 2020-11-16-24 |
The fabricator/manufacturer/facility name | Teichert Materials Hallwood | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA or name of Pit) | 91-58-0006::HALLWOOD PLANT |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Stockpile at the Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
The concrete mix design number | Lot number | ||
Sublot number | HMA Design ID |
Test Details
DIME Sample ID: 2020-11-16-37
DIME Test ID: 2020-11-16-37-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2021-01-11
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 12/16/2020
Individual mass retained on the 3/8 in. sieve: 0 grams
Individual mass retained on the #4 sieve: 2.8 grams
Individual mass retained on the #8 sieve: 53.8 grams
Individual mass retained on the #16 sieve: 86.9 grams
Individual mass retained on the #30 sieve: 120.7 grams
Individual mass retained on the #50 sieve: 158.8 grams
Individual mass retained on the #100 sieve: 59.4 grams
Individual mass retained on the #200 sieve: 18.8 grams
Individual mass retained on the pan: 9.6 grams
Total mass of sample tested: 511 grams
Cumulative percent passing the 3/8 in. sieve:100 %
Cumulative percent passing the #4 sieve:99 %
Cumulative percent passing the #8 sieve:89 %
Cumulative percent passing the #16 sieve:72 %
Cumulative percent passing the #30 sieve:48 %
Cumulative percent passing the #50 sieve:17 %
Cumulative percent passing the #100 sieve:6 %
Cumulative percent passing the #200 sieve:2 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/11/2021 ✔