Summary for Test 2015-04-10-7-1
Test performed: AASHTO T27-14Project Information
Project Identifiers | Project ID: 209866 DEA: 043G7604 EFIS: 0412000170 |
---|---|
DIST-CO-RTE-PM | 04-NAP-128-20.2 |
Award Date | 12/18/2014 |
Closeout Date | 12/14/2017 |
Work Description | INSTALL HORIZONTAL DRAINS, SLOPE INDICATORS, AND HIGHWAY PLANTING. |
Location Description | NAPA COUNTY NEAR CAPELL CREEK BRIDGE |
QA Service Level | 1 (Verified on 04/25/2016) |
Sample Information
Sample Taken Date | 04/10/2015 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/15/2015 |
Sample type | Verification | A brief description of the sample | 3/4 HMA |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Noel | Last name of sampler or witnessed by | Aquino |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 15ASPH-0198 thru 15ASPH-0203 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Syar Lake Herman | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Job Mix Formula Partial | Source Identification (SMARA, name of Pit or Job Site) | 91-48-0002 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Stockpile |
Where the material sample would have been placed if not sampled | Unknown | Superpave or Non-superpave Mix | Not set |
Test Details
DIME Sample ID: 2015-04-10-7
DIME Test ID: 2015-04-10-7-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2015-05-06
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Thomas Stinnett
Date of test: 04/27/2015
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 96 %
Cumulative percent passing the 1/2 in. sieve: 79 %
Cumulative percent passing the 3/8 in. sieve: 71 %
Cumulative percent passing the #4 sieve: 52 %
Cumulative percent passing the #8 sieve: 35 %
Cumulative percent passing the #16 sieve: 25 %
Cumulative percent passing the #30 sieve: 19 %
Cumulative percent passing the #50 sieve: 12 %
Cumulative percent passing the #100 sieve: 7 %
Cumulative percent passing the #200 sieve: 4 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/6/2015 ✔