Test 2020-12-14-5-1 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 214412
DEA: 11410404
EFIS: 1112000095
DIST-CO-RTE-PM11-IMP-8-R36.5/R37.5
Work DescriptionROADWAY, BRIDGE AND PLANT ESTABLISHMENT WORK.
Location DescriptionIMPERIAL COUNTY IN EL CENTRO FROM 0.4 MILE WEST OF IMPERIAL AVENUE OVERCROSSING TO 0.1 MILE EAST OF 8TH STREET OVERCROSSING
Sample Information
Sample Taken Date12/14/2020 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/16/2020
Sample typeQuality Assurance A brief description of the sample#7 x 4'-2" Dia hoops
The quantity of what the sample constitutes4 hoops From where was the sample collectedFabricator
First name of sampler or witnessed byOsiel Last name of sampler or witnessed byRamirez
Title of samplerQuality Assurance Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL123-126-20 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)457719
Hoop Manufacturer Lot Number(s)Lot 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size#7
Diameter of Hoop4'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade Steel
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2020-12-14-5
DIME Test ID: 2020-12-14-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-12-16
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 12/16/2020
UTM:400kip
Temperature:72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1127/22mm0.657223.2095372Ok Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 12/16/2020