Summary for Test 2020-07-06-39-6

Test performed: AASHTO T324-14

Project Information

Project IdentifiersProject ID: 214801
DEA: 031G6504
EFIS: 0319000105
DIST-CO-RTE-PM03-PLA,NEV-89-21.5/21.6,0.0/0.5
Award Date05/07/2020
Closeout Date03/16/2021
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE HMA (TYPE A).
Location DescriptionPLACER AND NEVADA COUNTIES IN AND NEAR TRUCKEE FROM WEST RIVER STREET TO 0.2 MILE NORTH OF DEERFIELD DRIVE
QA Service Level1 (Verified on 03/24/2020)

Sample Information

Sample Taken Date07/06/2020 Sample Unique Key39
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/07/2020
Sample typeVerification A brief description of the sample3/4 inch HMA - A w/RAP
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byRandy Last name of sampler or witnessed byStellhorn (WITNESS)
Title of samplerTeichert Personnel Telephone number of sampler
Laboratory sample identificationJMF20-031 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert - Martis Valley Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-06-39
DIME Test ID: 2020-07-06-39-6
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2020-12-16

Test Results


Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 08/03/2020
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 23300
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 12.74 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 6.43 mm
Stripping Inflection Point (Wheel A): 13900
Stripping Inflection Point (Wheel B): 25000
General comments (publicly viewable) (Max 1000 characters): JMF20-031

Test was verified on 12/16/2020