Test 2020-12-10-8-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 214937
DEA: 11288834
EFIS: 1117000088
DIST-CO-RTE-PM11-SD-11,125,905-various
Work DescriptionCONSTRUCT CONCRETE BRIDGE, PAVEMENT, BARRIER, AND INSTALL LIGHTING. HPLUL-6211(133) SR-125 SB to WB SR-905
Location DescriptionSAN DIEGO COUNTY IN AND NEAR SAN DIEGO AT ROUTE 11/125/905 SEPARATION
Sample Information
Sample Taken Date12/10/2020 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/14/2020
Sample typeQuality Assurance A brief description of the sample#9 (6'-5")
The quantity of what the sample constitutes244 From where was the sample collectedFabricator
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Laboratory sample identification
The fabricator/manufacturer/facility nameCMC Etiwanda Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-287-20 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4100020
Hoop Manufacturer Lot Number(s)1 and 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size#9
Diameter of Hoop6'-5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel AZ
Welding CompanyCMC Etiwanda Coating StandardsUncoated
Weld TypeFlash Welded
Test Details
DIME Sample ID: 2020-12-10-8
DIME Test ID: 2020-12-10-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-12-14
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 12/11/2020
UTM:400kip
Temperature:72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1219/29mm195758.3895758OK Neckingbewing

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 12/14/2020