Print Report | Back to Test Summary

Testing Report for 2020-11-20-3-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Matt Antonelli Structure Rep.: Faisal Zahlout

Sample Information

DIME Sample ID: 2020-11-20-3
TL Number from the TL Form:
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: (510) 385-8178
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 11/20/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/30/2020
The quantity of what the sample constitutes: 456 ea.
A brief description of the sample: #8 Thread Bar
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nucor Skyline

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 80
Threaded Bar Type: Deformed
Rebar Size: #8
Nut Specification for Threaded Bar: ASTM A29
System Manufacturer: Nucor
Epoxy Coating Color: NA
Threaded Bar Application:
Coating Standards: Uncoated
Bar Heat Number(s): 3700015150, 3700015151, 3700015152, BR1910025
Nut Heat Number(s): 8391409, 8391106
Bar Lot Number: N/A
Nut Lot Number: 5382, 5421, 5429
Coupler Heat Number(s): N/A
Coupler Grade: N/A

Test Information

DIME Test ID: 2020-11-20-3-1
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 12/08/2020
Date Tested: 12/07/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Bar & Nut stripped BR19100258 5429
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
No.8/25mm0.79105771941120Bar Nut Stripped 3700015151 5421fsaylor
Temperature 72 f
UTM 400kip