Print Report | Back to Sample Detail

Sample Record for 2020-05-13-38

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213485 DEA: 032F9804 EFIS: 0312000026 QA Service Level: 1
DIST-CO-RTE-PM: 03-COL-20-31.7/32.9
Work Description: PAVEMENT REHABILITATION
Location Description: COLUSA COUNTY IN AND NEAR COLUSA FROM 0.1 MILE EAST OF THE MARKET STREET/STATE ROUTE 20 INTERSECTION TO 0.1 MILE SOUTH OF BUTTE VISTA DRIVE
Contractor Name: A. TEICHERT & SON, INC. DBA TEICHERT CONSTRUCTION
Contractor Address: 24207 County Road 100A, Davis CA 95617
Resident Engineer: Anthony Granados Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-05-13-38
TL Number from the TL Form: C778171
Sample Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Sample Organization Contact: (530) 741-4238
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/13/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/14/2020
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: 1/2 inch HMA - A w/RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: JMF20-020B
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Teichert Hallwood

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 7

DIME Test ID: 2020-05-13-38-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 11/23/2020
Date Tested: 06/17/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-020B
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.40 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test 2 of 7

DIME Test ID: 2020-05-13-38-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 11/23/2020
Date Tested: 06/17/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-020B
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.463
Bulk Specific Gravity 2 2.471
Bulk Specific Gravity 3 2.457
Average Bulk Specific Gravity 2.464

Test 3 of 7

DIME Test ID: 2020-05-13-38-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 11/23/2020
Date Tested: 06/18/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-020B
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.570
Theoretical maximum density at 25°C (77°F) no data

Test 4 of 7

DIME Test ID: 2020-05-13-38-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 11/23/2020
Date Tested: 06/17/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-020B
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 4.2 %
Percent Air Voids 2 3.9
Percent Air Voids 3 4.4
Percent Air Voids Average 4.2

Test 5 of 7

DIME Test ID: 2020-05-13-38-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
This test has been superseded on 11/23/2020.
Reason: retested

Test 6 of 7

DIME Test ID: 2020-05-13-38-7
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Verified Date: 11/23/2020
Date Tested: 06/23/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-020B
Test Result Compliance: complies
Additional Comments When Verified:
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A) 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B) 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A) 2.79 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B) 3.61 mm
Stripping Inflection Point (Wheel A) 25000
Stripping Inflection Point (Wheel B) 25000

Test 7 of 7

DIME Test ID: 2020-05-13-38-8
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 11/23/2020
Date Tested: 06/18/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-020B
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 194 psi
Average Wet Tensile Strength 176 psi
Tensile Strength Ratio 91