Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213525 DEA: 010A0404 EFIS: 0100020013
QA Service Level: 1
DIST-CO-RTE-PM: 01-LAK-175-R25.0/27.5
Work Description: Putah Creek Bridge Widen +1 + 2RCBs
Location Description: LAKE COUNTY AT AND NEAR MIDDLETOWN FROM 0.1 MILE EAST OF PUTAH CREEK BRIDGE TO DRY CREEK BRIDGE
Contractor Name: GHILOTTI CONSTRUCTION CO. INC.
Contractor Address: 246 GHILOTTI AVENUE, SANTA ROSA, CA 95407
Resident Engineer: Dan Kraft Structure Rep.: Unknown
DIME Sample ID: 2020-10-27-10
TL Number from the TL Form: 827405
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 10/27/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/04/2020
The quantity of what the sample constitutes: 1 can
A brief description of the sample: RHMA #1 test
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: BoDean Company Santa Rosa
Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number: 1
Sublot number: 1
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2020-10-27-10-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 03/22/2021
Date Tested: 11/20/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Determination
|
Worked Penetration
|
Worked Penetration
|
26 0.1 mm
|
DIME Test ID: 2020-10-27-10-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 11/20/2020
Date Tested: 11/20/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used?
|
C
|
Softening Point Sample 1
|
74 C
|
Softening Point Sample 2
|
74 C
|
Bath Liquid
|
USP glycerin
|
Minutes Reaction
|
no data
|
DIME Test ID: 2020-10-27-10-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 11/20/2020
Date Tested: 11/20/2020
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Per 2018 Standard Specifications
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
25 C
|
Final Dial reading (F1)
|
76 mm
|
Ball Penetration (P1)
|
0 mm
|
Final Dial reading (F2)
|
74 mm
|
Ball Penetration (P2)
|
0 mm
|
Final Dial reading (F3)
|
74 mm
|
Ball Penetration (P3)
|
0 mm
|
Resilience 1
|
24 %
|
Resilience 2
|
26 %
|
Resilience 3
|
26 %
|
Average Resilience
|
25 %
|
Minutes Reaction
|
no data
|