Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 033F0904 Cty SAC Rte 5 PM Var Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Mohssen Ghassemi |
Date Reported: |
11/19/2020 |
|
Address: |
TL Number: |
114308 |
||
City: |
||||
Project Name: REPLACE STRUCTURAL CONCRETE BRIDGES, PLACE CIDH & CISS CONCRETE PILES. |
||||
Prime Contractor: Myers & Sons Construction |
||||
Sample Taken Date: |
10/21/2020 |
Mix Design: |
1615759 |
|
Contractor: Unknown |
Location: SACRAMENTO COUNTY AT NORTH SACRAMENTO UNDERCROSSING AND SACRAMENTO RIVER BRIDGE AND IN SAN JOAQUIN COUNTY AT MOKELUMNE RIVER BRIDGE |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.99 | 28.18 | 169154 | 6003.0 | 1 |
2 | 5.97 | 27.99 | 169437 | 6053.0 | 1 |
DIME Test ID: 2020-10-21-11-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6030
Age of specimen: 28 days
Certified By: Larry McCrum
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing