Print Report | Back to Test Summary

Testing Report for 2015-03-04-2-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 043A9214
EFIS: 0412000339
Project ID: 7467
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-880-22.6/24.0
Work Description: WIDEN FREEWAY, REPLACE OVERCROSSINGS, AND RECONSTRUCT RAMPS/ROADS.
Location Description: ALAMEDA COUNTY IN SAN LEANDRO FROM 0.4 MILE SOUTH OF MARINA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF ROUTE 112/880 SEPARATION
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Bahadur Singh
Structure Rep.: Bryan Chew

Sample Information

DIME Sample ID: 2015-03-04-2
TL Number from the TL Form: 15497794
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 227-7283
Type of Sample: Verification
Type of Material: Concrete
Sample Taken Date: 3/4/2015
Date that the sample was received by the laboratory/organization performing the testing: 3/9/2015
The quantity of what the sample constitutes: 2 6x12 concrete cylinders
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier: Unknown
Structure name: Unknown
The fabricator/manufacturer/facility name: Unknown

Material Information

The concrete mix design number: 1549779
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: Unknown
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2015-03-04-2-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Date Tested: 4/1/2015
Capped in accordance with: ASTM C617/CTM521
Verified Date: 4/1/2015
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Capped in accordance with?: ASTM C617/CTM521
Compressive strength (to nearest 10 psi): 6360 psi
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Compressive strength of cylinder 1: 6557.5 psi
Compressive strength of cylinder 2: 6158.8 psi
Maximum load on cylinder 1: 184199 lb
Maximum load on cylinder 2: 173000 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 28 days