Print Report | Back to Test Summary

Testing Report for 2020-10-22-3-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: STOCK-CHEM
EFIS: STOCK-CHEM
Project ID: 77777
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-10-22-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Materials Management Branch Field Office
Sample Organization Contact: (562) 500-5861
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/22/2020
Date that the sample was received by the laboratory/organization performing the testing: 11/3/2020
The quantity of what the sample constitutes: 1 of 25
A brief description of the sample: 3"-4 x 60" ASTM F1554-15 Gr. 55=S1 D.E. Stud
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMC Steel

Material Information

Rocap Number(s):
Heat Number(s): 3094722
Nut Mfg. Lot Number(s): XSF2
Washer Mfg. Lot Number(s): 3326
Bolt Specification: ASTM F1554-15 Gr. 55-S1
Bolt Length(s): 60"
Nut Specification: ASTM A194-14a Grade 2H
Washer Specification: F436 S
Finish: HDG
Diameter/Size: 3"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2020-10-22-3-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Date Tested: 11/6/2020
Verified Date: 11/9/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 1
Sample Heat Number Diameter (in) Area (sqin) Stress at Offset (psi) Tensile Strength (psi) Elongation in 4 x d (%) Tested By
2 3094722 0.504 0.2 66577 92051 26.4 fsaylor
UTM: 67kip
Temperature: 72 f