Print Report | Back to Sample Detail

Sample Record for 2020-10-24-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213746 DEA: 080Q75U4 EFIS: 0817000114 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2
Work Description: REPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS
Location Description:
Contractor Name: J McLoughlin Engineering
Contractor Address: 10641 Fulton Court, Rancho Cucamonga, CA 91730
Resident Engineer: Mujahid Qureshi Structure Rep.: Ching Chuang

Sample Information

DIME Sample ID: 2020-10-24-2
TL Number from the TL Form: 999-1024A
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/24/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/27/2020
The quantity of what the sample constitutes: 6 CYLINDERS RSLCB
A brief description of the sample: RSLCB CYLINDERS
From where was the sample collected: Job Site
Laboratory sample identification: 999-1024A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SHORTLOAD CONCRETE

Material Information

The concrete mix design number: CTS 30 RAM
The truck number from where the sample was collected: 6
The batch plant ticket number from where the sample was collected: NOT PROVIDED
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: SITE
Where the material sample would have been placed if not sampled: WB 60 HAVEN TO MILLIKAN TAPER 1ST LOCATION STA 45985 TO 44324 AND 43025 TO 43025
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2020-10-24-2-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/02/2020
Date Tested: 10/31/2020
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 6
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Average diameter of cylinder 3 6.01 in
Average diameter of cylinder 4 6.01 in
Average diameter of cylinder 5 6.01 in
Average diameter of cylinder 6 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Cross sectional area of cylinder 3 28.37 in^2
Cross sectional area of cylinder 4 28.37 in^2
Cross sectional area of cylinder 5 28.37 in^2
Cross sectional area of cylinder 6 28.27 in^2
Compressive strength (to nearest 10 psi) 3370 psi
Maximum load on cylinder 1 99885 lb
Maximum load on cylinder 2 95640 lb
Maximum load on cylinder 3 91620 lb
Maximum load on cylinder 4 96320 lb
Maximum load on cylinder 5 92650 lb
Maximum load on cylinder 6 95810 lb
Compressive strength of cylinder 1 3533.3 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 3383.1 psi
Compressive strength of cylinder 3 3229.5 psi
Compressive strength of cylinder 4 3395.1 psi
Compressive strength of cylinder 5 3265.8 psi
Compressive strength of cylinder 6 3389.1 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 3
Type of fracture pattern of cylinder 4 2
Type of fracture pattern of cylinder 5 3
Type of fracture pattern of cylinder 6 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Correction factor for cylinder 4 1
Correction factor for cylinder 5 1
Correction factor for cylinder 6 1
Age of specimen 7 days
Age of specimen in hours no data