Print Report | Back to Test Summary

Testing Report for 2020-10-19-6-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 120P5804
EFIS: 1215000148
Project ID: 214939
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-90-2.6/5.1
Work Description: COLD PLANE AC, PLACE RHMA, REPLACE ROADSIDE SIGNS, LOOPS & RESTRIPE.
Location Description: ORANGE COUNTY IN FULLERTON AND BREA FROM HARBOR BOULEVARD TO RANDOLPH AVENUE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Osama Francis
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-10-19-6
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 10/19/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/22/2020
The quantity of what the sample constitutes: 4 Bags of Coldfeed Agg., 1 Bag Rap
A brief description of the sample: JMF 3/8" HMA-A-SP, R15,0.25% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0632A-20
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: R J Noble Orange

Material Information

Source Identification (SMARA or name of Pit): 91-33-0035
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number: 44R1501SPWO
A detailed description of where the material sample was collected: Belt Cut at RJ Noble Orange Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/8 inch
The concrete mix design number:
Lot number:
Sublot number:

Test Information

DIME Test ID: 2020-10-19-6-8
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Date Tested: 10/29/2020
Verified Date: 10/30/2020
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

What test method is performed?: Method A
Bulk dry specific gravity: 2.641
Average uncompacted voids: 49.4 %