Print Report | Back to Test Summary

Testing Report for 2020-10-23-1-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 120K0224
EFIS: 1214000097
Project ID: 213750
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-14.5/17.1
Work Description: South County Improvement Project (Phase 2 - Oso/Alicia) CONST BRIDGES, RW, SW, HMA PVMT, JPCP, DRAINAGE, AND ELECT SYSTEMS.
Location Description: ORANGE COUNTY IN MISSION VIEJO AND LAGUNA HILLS FROM 0.7 MILE SOUTH OF OSO PARKWAY OVERCROSSING TO 0.3 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: John Hong
Structure Rep.: Sara Soleimani

Sample Information

DIME Sample ID: 2020-10-23-1
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 10/23/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/26/2020
The quantity of what the sample constitutes: 4
A brief description of the sample: #7 Headed Bar - Button Head 07BNX
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Integrity Rebar Placers

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 1202021682
Head Manufacturer Lot Number(s): Lot 2
Rebar Size: #7
Headed Bar Model Name: 07BNX 8G2
Size of Head: Full Size - 9x
Head Connection Type: Crimped Head
Head Shape: Circular
Rebar Manufacturer: Nucor
Head Manufacturer: BarSplice Products
Head Fabricator: Integrity Rebar Placers
Material Standard Code: ASTM A706

Test Information

DIME Test ID: 2020-10-23-1-2
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Date Tested: 10/27/2020
Verified Date: 10/27/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Headed Bar Samples: 1
Lot # Area (sqin) Peak Load (lbf) Tensile Strength (psi) Comments Tested By
2 0.6 60438 100731 OK Necking spaine
Temperature: 72 f
UTM: 400kip