Print Report | Back to Test Summary

Testing Report for 2020-10-16-7-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 081H3414
EFIS: 0818000172
Project ID: 214848
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-210,215,259-Various
Work Description: PLACE RHMA-G, COLD PLANE AC AND REPLACE AC SURFACING.
Location Description: SAN BERNARDINO COUNTY ON ROUTE 210, 215 AND 259 AT VARIOUS LOCATIONS
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Samer Georges
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-10-16-7
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 10/16/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/19/2020
The quantity of what the sample constitutes: 2 boxes 79.21 tons out
A brief description of the sample: 3/4" HMA-A R15 PG64-28M
From where was the sample collected: Manufacturer
Laboratory sample identification: 0617A-20
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt - Corona

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 1
Sublot number: 5

Test Information

DIME Test ID: 2020-10-16-7-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Asphalt Binder Content)
Date Tested: 10/21/2020
Verified Date: 10/23/2020
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

Asphalt Binder Content: 4.50 %
Correction Factor (Percent by mass of HMA Specimen): no data