Print Report | Back to Test Summary

Testing Report for 2020-10-08-7-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 030H4804
EFIS: 0315000198
Project ID: 214175
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-99-0.1/1.6,11.8/21.6
Work Description: COLD PLANE AC PAVEMENT AND RHMA OVERLAY.
Location Description: SACRAMENTO COUNTY IN AND NEAR GALT FROM DRY CREEK BRIDGE TO SIMMERHORN ROAD AND IN ELK GROVE AND SACRAMENTO FROM 0.9 MILE SOUTH OF ELK GROVE BOULEVARD TO MARTIN LUTHER KING JR BOULEVARD
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Sushma Lee
Structure Rep.: Kim Noonan

Sample Information

DIME Sample ID: 2020-10-08-7
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/8/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/20/2020
The quantity of what the sample constitutes: 52
A brief description of the sample: 1/2-13 X 1 1/4 A325 Hvy Hex Bolt
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Structural and Steel Products

Material Information

Rocap Number(s): 091620A
Heat Number(s): 100792173
Nut Mfg. Lot Number(s): 414845B
Washer Mfg. Lot Number(s): D9266
Bolt Specification: A325
Bolt Length(s): 1 1/4"
Nut Specification: A563
Washer Specification: F436
Finish: MG
Diameter/Size: 1/2"
Bolt Mfg. Lot Number: 406819A
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Information

DIME Test ID: 2020-10-08-7-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Date Tested: 10/22/2020
Verified Date: 10/27/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 406819A
Finish Coating: ASTM B695 - Mech Galv
Product Markings: A325 USA N
Size: .5 in
Bolt Length: 1.25 in
Measurement Average: 2.96 mils