Print Report | Back to Sample Detail

Sample Record for 2020-10-15-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66667 DEA: JMFPP EFIS: 0019000043 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-10-15-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Sample Organization Contact: (510) 507-3456
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 10/15/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/15/2020
The quantity of what the sample constitutes: 8 Bags
A brief description of the sample: 8 Bags of Aggregate
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Syar Industries

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-49-0004::CANYON ROCK CO., INC.
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Canyon Rock
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 4

DIME Test ID: 2020-10-15-2-1
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 10/16/2020
Date Tested: 09/21/2020
Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Organization Address: 111 Grand Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94623
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 286-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity 2.585
Bulk specific gravity (SSD Basis) 2.632
Apparent specific gravity 2.712
Absorption 1.8 %

Test 2 of 4

DIME Test ID: 2020-10-15-2-2
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 10/16/2020
Date Tested: 10/15/2020
Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Organization Address: 111 Grand Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94623
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 286-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.665
Absorption 0.7 %

Test 3 of 4

DIME Test ID: 2020-10-15-2-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 10/16/2020
Date Tested: 09/17/2020
Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Organization Address: 111 Grand Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94623
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 286-4717
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 2
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.465
Specific Gravity for Sample 2 2.466
Average Specific Gravity 2.456
Theoretical maximum density at 25°C (77°F) no data

Test 4 of 4

DIME Test ID: 2020-10-15-2-4
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 10/16/2020
Date Tested: 09/15/2020
Submitted By Organization: CT D04 - Hayward DME / District Laboratory
Organization Address: 111 Grand Avenue,
Organization City: Oakland
Organization State: CA
Organization Zipcode: 94623
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 286-4717
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 96.1 %
Cumulative percent passing the 3/8 in. sieve 80.1 %
Cumulative percent passing the #4 sieve 57.7 %
Cumulative percent passing the #8 sieve 37.9 %
Cumulative percent passing the #16 sieve 20.3 %
Cumulative percent passing the #30 sieve 11.4 %
Cumulative percent passing the #50 sieve 7.3 %
Cumulative percent passing the #100 sieve 5.1 %
Cumulative percent passing the #200 sieve 3.8 %