Print Report | Back to Test Summary

Testing Report for 2020-10-08-27-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 033F0904
EFIS: 0312000056
Project ID: 214176
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC,SJ-5,160-Var
Work Description: REPLACE STRUCTURAL CONCRETE BRIDGES, PLACE CIDH & CISS CONCRETE PILES.
Location Description: SACRAMENTO COUNTY AT NORTH SACRAMENTO UNDERCROSSING AND SACRAMENTO RIVER BRIDGE AND IN SAN JOAQUIN COUNTY AT MOKELUMNE RIVER BRIDGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mohssen Ghassemi
Structure Rep.: Chuck Pazzi

Sample Information

DIME Sample ID: 2020-10-08-27
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 10/8/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/12/2020
The quantity of what the sample constitutes: 2
A brief description of the sample: Coupon Casting
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Farrar

Material Information

Heat Number (s): H040
Part Number (s): 68 27 172
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Farrar Corporation
Prestressing Manufacturer: DSI

Test Information

DIME Test ID: 2020-10-08-27-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Date Tested: 10/15/2020
Verified Date: 10/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Samples: 2
Sample Heat Number Diameter (in) Area (sqin) Stress at Offset (psi) Tensile Strength (psi) Elongation in 4 x d (%) Tested By
H040 0.5 0.19635 62300 108976 11.1 bewing
H040 0.5 0.19635 62187 109213 11.1 bewing
UTM: 67kip
Temperature: 72 F