Print Report | Back to Test Summary

Testing Report for 2020-10-06-1-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 024F5904
EFIS: 0213000010
Project ID: 214099
QA Service Level: 1
DIST-CO-RTE-PM: 02-TEH-5-R25.4
Work Description: BRIDGE SEISMIC RETROFIT AND SCOUR REPAIR.
Location Description: TEHAMA COUNTY IN RED BLUFF AT SACRAMENTO RIVER BRIDGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mike Z'denek
Structure Rep.: Ryan Duran

Sample Information

DIME Sample ID: 2020-10-06-1
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 10/6/2020
Date that the sample was received by the laboratory/organization performing the testing: 10/9/2020
The quantity of what the sample constitutes: 1 Lot
A brief description of the sample: Micro Pile All Thread Bar
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Engineering San Diego

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 150
Threaded Bar Type: Deformed
Rebar Size: #10
Nut Specification for Threaded Bar: A29
System Manufacturer: Williams Form Engineering
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s): 62150556
Nut Heat Number(s): 75075291 Code 32U5D
Bar Lot Number: 1
Nut Lot Number: 1
Coupler Heat Number(s): 100102769 Code 32M6D
Coupler Grade: 150 ksi

Test Information

DIME Test ID: 2020-10-06-1-1
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Date Tested: 10/13/2020
Verified Date: 10/14/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: A722 Bar Nut & Coupler
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Threaded Bar Samples: 1
Sample Size Mfg Lot Area (sqin) Tensile Strength (psi) Stress at Offset (psi) Total Elongation (%) Reduction of area (%) Comments Tested By
1 ASTM A722 Type II Deformed Bar 1 1/4 : 32mm 62150556 1.25 152093.71 142.73 0 100 A722 Bar Nut & Coupler fsaylor
Temperature: 72 f
UTM: 2000kip