Print Report | Back to Sample Detail

Sample Record for 2020-09-25-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214629 DEA: 051H9304 EFIS: 0517000017 QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-46-R17.2/R17.6
Work Description: CONSTRUCT ROUNDABOUT.
Location Description: SAN LUIS OBISPO COUNTY NEAR TEMPLETON FROM 0.2 MILE WEST TO 0.2 MILE EAST OF VINEYARD DRIVE
Contractor Name: CAL PORTLAND CONSTRUCTION
Contractor Address: 1625 E Donovan Road, Santa Maria, CA 93454
Resident Engineer: Rick Silva Structure Rep.: Salvador J Heredia

Sample Information

DIME Sample ID: 2020-09-25-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Acceptance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 09/25/2020
Date that the sample was received by the laboratory/organization performing the testing: 09/29/2020
The quantity of what the sample constitutes: 2
A brief description of the sample: #8 ASTM A615 Grade 75 Soil Nail
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Engineering-SD

Material Information

Production or Authorization Testing: Authorization Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Plain
Rebar Size: #8
Nut Specification for Threaded Bar: n/a
System Manufacturer: Williams Form Engineering
Epoxy Coating Color: Purple
Threaded Bar Application: Soil Nail
Coating Standards: ASTM A934 epoxy
Bar Heat Number(s): 100104509
Nut Heat Number(s):
Bar Lot Number: 10010450920
Nut Lot Number:
Coupler Heat Number(s):
Coupler Grade:

Test Results

Test 1 of 4

DIME Test ID: 2020-09-25-2-1
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 10/01/2020
Date Tested: 09/30/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Threaded Bar
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
No.8/25mm0.79122090945038.57A615 Threaded Barfsaylor
Temperature 72 f
UTM 400kip

Test 2 of 4

DIME Test ID: 2020-09-25-2-2
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 10/01/2020
Date Tested: 09/30/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Threaded Bar
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
No.8/25mm0.79122130952370A615 Threaded Barfsaylor
Temperature 72 f
UTM 400kip

Test 3 of 4

DIME Test ID: 2020-09-25-2-3
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 10/01/2020
Date Tested: 09/30/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean 10.96 mils
Second Bar Mean 10.41 mils
Lower spec. limit LSL 10 mils
Upper spec. limit USL 15 mils
Total mean value 10.69 mils
Total number of values less than LSL no data
Total number of values greater than USL no data

Test 4 of 4

DIME Test ID: 2020-09-25-2-4
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 10/01/2020
Date Tested: 09/30/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday 0
Total Length 8
Holidays Per Linear Foot of Bar 0
Holiday Test Pass/Fail Pass