Sample Record for 2020-09-25-2
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214629 DEA: 051H9304 EFIS: 0517000017
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-46-R17.2/R17.6
Work Description: CONSTRUCT ROUNDABOUT.
Location Description: SAN LUIS OBISPO COUNTY NEAR TEMPLETON FROM 0.2 MILE WEST TO 0.2 MILE EAST OF VINEYARD DRIVE
Contractor Name: CAL PORTLAND CONSTRUCTION
Contractor Address: 1625 E Donovan Road, Santa Maria, CA 93454
Resident Engineer: Rick Silva Structure Rep.: Salvador J Heredia
Sample Information
DIME Sample ID: 2020-09-25-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Acceptance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 09/25/2020
Date that the sample was received by the laboratory/organization performing the testing: 09/29/2020
The quantity of what the sample constitutes: 2
A brief description of the sample: #8 ASTM A615 Grade 75 Soil Nail
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Engineering-SD
Material Information
Production or Authorization Testing: Authorization Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Plain
Rebar Size: #8
Nut Specification for Threaded Bar: n/a
System Manufacturer: Williams Form Engineering
Epoxy Coating Color: Purple
Threaded Bar Application: Soil Nail
Coating Standards: ASTM A934 epoxy
Bar Heat Number(s): 100104509
Nut Heat Number(s):
Bar Lot Number: 10010450920
Nut Lot Number:
Coupler Heat Number(s):
Coupler Grade:
Test Results
Test 1 of 4
DIME Test ID: 2020-09-25-2-1
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 10/01/2020
Date Tested: 09/30/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Threaded Bar
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By | | No.8/25mm | | 0.79 | 122090 | 94503 | 8.57 | A615 Threaded Bar | fsaylor |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
Test 2 of 4
DIME Test ID: 2020-09-25-2-2
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 10/01/2020
Date Tested: 09/30/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Threaded Bar
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By | | No.8/25mm | | 0.79 | 122130 | 95237 | 0 | A615 Threaded Bar | fsaylor |
| |
Temperature
|
72 f
|
UTM
|
400kip
|
Test 3 of 4
DIME Test ID: 2020-09-25-2-3
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 10/01/2020
Date Tested: 09/30/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
10.96 mils
|
Second Bar Mean
|
10.41 mils
|
Lower spec. limit LSL
|
10 mils
|
Upper spec. limit USL
|
15 mils
|
Total mean value
|
10.69 mils
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|
Test 4 of 4
DIME Test ID: 2020-09-25-2-4
Test Method: ASTM A884-13: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 10/01/2020
Date Tested: 09/30/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
8
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|