Print Report | Back to Sample Detail

Sample Record for 2020-06-16-49

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215041 DEA: 031J1904 EFIS: 0320000169 QA Service Level: 1
DIST-CO-RTE-PM: 03-YUB,YUB/SUT-70,70,99-Var
Work Description: In-kind restoration pvmt. repair w/HMA medium overlay, striping, traffic control, incidental work
Location Description: Yubat & Sutter Counties at various locaitons
Contractor Name: George Reed INC
Contractor Address: 140 Empire Avenue, Modesto, CA 95354
Resident Engineer: Donald Ward Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-06-16-49
TL Number from the TL Form:
Sample Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Sample Organization Contact: (530) 741-4238
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 06/16/2020
Date that the sample was received by the laboratory/organization performing the testing: 06/16/2020
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: 3/4 inch HMA-A
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: George Reed - Rio Linda

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-58-0001::WESTERN AGGREGATES
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Windrow at the Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 8

DIME Test ID: 2020-06-16-49-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 09/09/2020
Date Tested: 07/30/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-025
Test Result Compliance: complies
Additional Comments When Verified:
Method 2 - Individual Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced and Fine 1 Faced
Weighted average percentage of fractured, coarse, 2 faced particles 97 %
Weighted average percentage of fractured, coarse, 1 faced particles 99 %
Percentage of fractured, fine, 1 faced particles tested 99 %

Test 2 of 8

DIME Test ID: 2020-06-16-49-3
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 09/09/2020
Date Tested: 07/30/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-025
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation C
Percent loss after 100 revolutions 3 %
Percent loss after 500 revolutions 15 %

Test 3 of 8

DIME Test ID: 2020-06-16-49-4
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 09/09/2020
Date Tested: 07/30/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-025
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 73

Test 4 of 8

DIME Test ID: 2020-06-16-49-5
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 09/09/2020
Date Tested: 07/30/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-025
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.671
Average uncompacted voids 46.6 %

Test 5 of 8

DIME Test ID: 2020-06-16-49-6
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 09/09/2020
Date Tested: 07/30/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-025
Test Result Compliance: complies
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.773
Absorption 0.9 %

Test 6 of 8

DIME Test ID: 2020-06-16-49-7
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 09/09/2020
Date Tested: 07/30/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-025
Test Result Compliance: complies
Additional Comments When Verified:
Bulk specific gravity 2.671
Bulk specific gravity (SSD Basis) 2.729
Apparent specific gravity 2.837
Absorption 2.2 %

Test 7 of 8

DIME Test ID: 2020-06-16-49-8
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
This test has been superseded on 09/10/2020.
Reason: corrected

Test 8 of 8

DIME Test ID: 2020-06-16-49-9
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 09/10/2020
Date Tested: 07/30/2020
Submitted By Organization: CT D03 - Olivehurst Northern Regional Laboratory
Organization Address: 5330 Arboga Road,
Organization City: Olivehurst
Organization State: CA
Organization Zipcode: 95961
Organization Email: jeff.herbert@dot.ca.gov
Organization Phone: (530) 741-4238
General Comments for this Test: JMF20-025
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 98 %
Cumulative percent passing the 1/2 in. sieve 76 %
Cumulative percent passing the 3/8 in. sieve 61 %
Cumulative percent passing the #4 sieve 43 %
Cumulative percent passing the #8 sieve 30 %
Cumulative percent passing the #16 sieve 21 %
Cumulative percent passing the #30 sieve 14 %
Cumulative percent passing the #50 sieve 9 %
Cumulative percent passing the #100 sieve 6 %
Cumulative percent passing the #200 sieve 4.2 %