Print Report | Back to Sample Detail

Sample Record for 2020-08-19-27

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-08-19-27
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Acceptance
Type of Material: SMTL TM10 - Wire Rope Choker
Sample Taken Date: 08/19/2020
Date that the sample was received by the laboratory/organization performing the testing: 09/03/2020
The quantity of what the sample constitutes: 10
A brief description of the sample: Wire Rope
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Oakland Caltrans paint Crew

Material Information

Reel Number: Unknown
Painter Name or ID: Unknown
Material Specification: ASTM A931
Size: 5/16 in
Wire Manufacturer:
Material Collected to Test: Operator

Test Results

Test 1 of 11

DIME Test ID: 2020-08-19-27-1
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 09/08/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Break
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10754.2
Operator Thomas Annis
Location of Failure Below Crimp

Test 2 of 11

DIME Test ID: 2020-08-19-27-2
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 09/08/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Break
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10733.6
Operator Jesse Saylor
Location of Failure Below Crimp

Test 3 of 11

DIME Test ID: 2020-08-19-27-3
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 09/08/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Break
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10705
Operator Hernan Machan
Location of Failure Below Crimp

Test 4 of 11

DIME Test ID: 2020-08-19-27-4
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 09/08/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Break
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10780.1
Operator Corey Avaloz
Location of Failure Below Crimp

Test 5 of 11

DIME Test ID: 2020-08-19-27-5
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 09/08/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Break
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10850
Operator Thanar Aderson
Location of Failure Below Crimp

Test 6 of 11

DIME Test ID: 2020-08-19-27-6
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 09/08/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Break
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10734.8
Operator michael Cabero
Location of Failure Below Crimp

Test 7 of 11

DIME Test ID: 2020-08-19-27-7
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 09/08/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Break
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10862.6
Operator Devin Czarnecki
Location of Failure Below Crimp

Test 8 of 11

DIME Test ID: 2020-08-19-27-8
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 09/08/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Break
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10777
Operator Marcos Flores
Location of Failure Below Crimp

Test 9 of 11

DIME Test ID: 2020-08-19-27-9
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 09/08/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Break
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10841.7
Operator Micheal Cuoco
Location of Failure Below Crimp

Test 10 of 11

DIME Test ID: 2020-08-19-27-10
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 09/08/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Break
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10813.4
Operator S138696
Location of Failure Below Crimp

Test 11 of 11

DIME Test ID: 2020-08-19-27-11
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 09/08/2020
Date Tested: 09/08/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: OK Break
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67kip
Specimen Identification Wire Rope
Peak Load 10583
Operator Christiana Valentine
Location of Failure Below Crimp