Print Report | Back to Sample Detail

Sample Record for 2020-06-08-46

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214589 DEA: 020J1604 QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-284-0.0/8.3
Work Description: PLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING).
Location Description: PLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: 24339 STATE HIGHWAY 89 N.;, BURNEY CA 96013
Resident Engineer: Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-06-08-46
TL Number from the TL Form: 733200
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/08/2020
Date that the sample was received by the laboratory/organization performing the testing: 06/09/2020
The quantity of what the sample constitutes: JMF Verification and PSE
A brief description of the sample: 3/4-inch Type A HMA (eq. PG 64-16) 23.0 RAP, 1.0 Lime
From where was the sample collected: Manufacturer
Laboratory sample identification: D78459
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Ward Lake Plant, Litchfield, CA

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 7

DIME Test ID: 2020-06-08-46-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/27/2020
Date Tested: 06/26/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2103.9 g
Corrected Asphalt Binder Content 5.51 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) 0.64 %
Moisture Content 0.00 %
Temperature Compensation Factor no data
Test Temperature 1000 F

Test 2 of 7

DIME Test ID: 2020-06-08-46-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/27/2020
Date Tested: 06/09/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7338.0 grams
Mass of oven-dry sample in air for Sample 1 2521.0 grams
Mass of container filled with the sample and water for Sample 1 8829.0 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.447
Theoretical maximum density at 25°C (77°F) no data

Test 3 of 7

DIME Test ID: 2020-06-08-46-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/27/2020
Date Tested: 06/10/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity 2.325
Bulk Specific Gravity 2 2.324
Bulk Specific Gravity 3 2.327
Average Bulk Specific Gravity 2.325

Test 4 of 7

DIME Test ID: 2020-06-08-46-5
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/27/2020
Date Tested: 06/11/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 5.0 %
Percent Air Voids 2 5.0
Percent Air Voids 3 4.9
Percent Air Voids Average 5.0

Test 5 of 7

DIME Test ID: 2020-06-08-46-6
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 08/27/2020
Date Tested: 06/13/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 147 psi
Average Wet Tensile Strength 124 psi
Tensile Strength Ratio 0.84

Test 6 of 7

DIME Test ID: 2020-06-08-46-7
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Verified Date: 08/27/2020
Date Tested: 06/15/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A) 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B) 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A) 3 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B) 3.7 mm
Stripping Inflection Point (Wheel A) >25000
Stripping Inflection Point (Wheel B) >25000

Test 7 of 7

DIME Test ID: 2020-06-08-46-8
Test Method: AASHTO T312-14: Preparing and Determining the Density of Asphalt Mixture Specimens by Means of the Superpave Gyratory Compactor (Method of Compaction)
Verified Date: 08/27/2020
Date Tested: 06/10/2020
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Uncorrected relative density (Gmmu8) 83.6 %
Uncorrected relative density (Gmmu85) 91.9 %
Uncorrected relative density (Gmmu130) 93.2 %
Air Voids (AV8) 13.8 %
Air Voids (AV85) 5.2 %
Air Voids (AV130) 3.9 %