Print Report | Back to Sample Detail

Sample Record for 2020-07-15-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214601 DEA: 041J5694 EFIS: 0419000313 QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-101-0.0/21.8
Work Description: San Mateo US 101 Express Lanes North
Location Description:
Contractor Name: KIEWIT INFRASTRUCTURE COMPANY
Contractor Address: 1301 SHOREWAY RD, SUITE 275, BELMONT, CA 94402
Resident Engineer: Douglas Inori Structure Rep.: Tyler Pinell

Sample Information

DIME Sample ID: 2020-07-15-5
TL Number from the TL Form:
Sample Submitted By Organization: CT METS QASI - Los Angeles Design Build Field Laboratory
Sample Organization Contact: (619) 204-7248
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 07/15/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/15/2020
The quantity of what the sample constitutes: 25 pcs
A brief description of the sample: ASTM A325 1-1/4"x 3-3/4" Bolt
From where was the sample collected: Manufacturer
Laboratory sample identification: L149-073-20
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Structural and Steel Products

Material Information

Rocap Number(s): 060920CR
Heat Number(s): Bolt 100893998, Nut DL17100198
Nut Mfg. Lot Number(s): 388517A
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM A325
Bolt Length(s): 3-3/4"
Nut Specification: ASTM A563
Washer Specification: n/a
Finish: Mech.Zinc Galv. ASTM B695
Diameter/Size: 1-1/4"x 3-3/4"
Bolt Mfg. Lot Number: 416756A
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 7

DIME Test ID: 2020-07-15-5-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 08/19/2020
Date Tested: 08/18/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Bolt
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
3A416756A1.2500137406611.216.00A325 Boltfsaylor
UTM 450kip
Temperature no data

Test 2 of 7

DIME Test ID: 2020-07-15-5-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 08/19/2020
Date Tested: 08/18/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Proff Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
3A388517A149734Proff Loadfsaylor
UTM 450kip
Temperature 72 f

Test 3 of 7

DIME Test ID: 2020-07-15-5-3
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 08/19/2020
Date Tested: 08/18/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Proff Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
4A388517A149759Proff Loadfsaylor
UTM 450kip
Temperature 72 f

Test 4 of 7

DIME Test ID: 2020-07-15-5-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 08/19/2020
Date Tested: 08/18/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 416756A
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 N USA
Size 1.250 in
Bolt Length 3.75 in
Gage Type Pass

Test 5 of 7

DIME Test ID: 2020-07-15-5-5
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 08/19/2020
Date Tested: 08/18/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 388517A
Finish Coating ASTM B695 - Mech Galv
Product Markings DH N
Size 1.250 in
Gage Type NA

Test 6 of 7

DIME Test ID: 2020-07-15-5-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/19/2020
Date Tested: 08/18/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 416756A
Finish Coating ASTM B695 - Mech Galv
Product Markings A325 N USA
Size 1.250 in
Bolt Length 3.75 in
Measurement Average 3.13 mils

Test 7 of 7

DIME Test ID: 2020-07-15-5-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 08/19/2020
Date Tested: 08/18/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 3A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 388517A
Finish Coating ASTM B695 - Mech Galv
Product Markings DH N
Size 1.250 in
Bolt Length no data in
Measurement Average 3.2 mils