Print Report | Back to Sample Detail

Sample Record for 2020-08-04-15

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214731 DEA: 051M0004 EFIS: 0519000047 QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-101-16.5/R21.5
Work Description: COLD PLANE AND RHMA-GAP GRADED OVERLAY ON EXISTING ROADWAY.
Location Description: SAN LUIS OBISPO COUNTY IN AND NEAR PISMO BEACH FROM 0.1 MILE SOUTH OF PRICE CANYON ROAD TO SAN LUIS CREEK BRIDGE
Contractor Name: PAPICH CONSTRUCTION COMPANY, INC.
Contractor Address: 398 SUNRISE TERRACE, ARROYO GRANDE, CA 93425
Resident Engineer: Lilian Bennetzen Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-08-04-15
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 08/04/2020
Date that the sample was received by the laboratory/organization performing the testing: 08/05/2020
The quantity of what the sample constitutes: One JMF Verification
A brief description of the sample: Bags of Treated and Untreated
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SPM Templeton

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-10-0006
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Stockpile at Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 7

DIME Test ID: 2020-08-04-15-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 08/10/2020
Date Tested: 08/07/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 95.1 %
Cumulative percent passing the 3/8 in. sieve 80 %
Cumulative percent passing the #4 sieve 40.6 %
Cumulative percent passing the #8 sieve 22.6 %
Cumulative percent passing the #16 sieve 12.5 %
Cumulative percent passing the #30 sieve 7 %
Cumulative percent passing the #50 sieve 4.1 %
Cumulative percent passing the #100 sieve 2.4 %
Cumulative percent passing the #200 sieve 1.3 %

Test 2 of 7

DIME Test ID: 2020-08-04-15-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 08/10/2020
Date Tested: 08/10/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method 2 - Individual Fracture Determination
Aggregate Size and Fracture Type Coarse 2 Faced and Fine 1 Faced
Weighted average percentage of fractured, coarse, 2 faced particles 98 %
Percentage of fractured, fine, 1 faced particles tested 97 %

Test 3 of 7

DIME Test ID: 2020-08-04-15-3
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 08/10/2020
Date Tested: 08/10/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation C
Percent loss after 100 revolutions 7 %
Percent loss after 500 revolutions 33 %

Test 4 of 7

DIME Test ID: 2020-08-04-15-4
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 08/10/2020
Date Tested: 08/07/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 75

Test 5 of 7

DIME Test ID: 2020-08-04-15-5
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 08/10/2020
Date Tested: 08/10/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method A
Determination By Mass
Dimensional ratio used 5:1
Weighted percentage of particles (by mass) that were flat 0 %
Weighted percentage of particles (by mass) that were elongated 0 %
Weighted percentage of particles (by mass) that were both flat and elongated 0 %
Weighted percentage of particles (by mass) that were neither flat nor elongated 100 %

Test 6 of 7

DIME Test ID: 2020-08-04-15-6
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 08/10/2020
Date Tested: 08/07/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.593
Absorption 1.7 %

Test 7 of 7

DIME Test ID: 2020-08-04-15-7
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 08/10/2020
Date Tested: 08/07/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity 2.529
Bulk specific gravity (SSD Basis) 2.593
Apparent specific gravity 2.704
Absorption 2.6 %