Print Report | Back to Sample Detail

Sample Record for 2020-08-06-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214733 DEA: 060R1104 EFIS: 0614000030 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE,KER-119,198-Var
Work Description: CULVERT REPLACEMENT.
Location Description: FRESNO AND KERN COUNTIES AT VARIOUS LOCATIONS.
Contractor Name: CCFG CONSTRUCTION
Contractor Address: 17750 Wards Ferry Road, Sonoma, CA, 95370
Resident Engineer: Robert Decker Structure Rep.: Evan Stensvad

Sample Information

DIME Sample ID: 2020-08-06-10
TL Number from the TL Form:
Sample Submitted By Organization: Rinker Materials
Sample Organization Contact: (916) 381-3910
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/06/2020
Date that the sample was received by the laboratory/organization performing the testing: 08/07/2020
The quantity of what the sample constitutes: 1 days production
A brief description of the sample: CONCRETE
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Forterra Pipe and Precast, Florin Rd

Material Information

The concrete mix design number: mix 5
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 001
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: conveyor belt
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2020-08-06-10-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/10/2020
Date Tested: 08/07/2020
Submitted By Organization: Rinker Materials
Organization Address: 7020 Tokay Avenue,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95828
Organization Email: Edgar.Benitez@Rinkerpipe.com
Organization Phone: (209) 401-6972
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 2470 psi
Maximum load on cylinder 1 71435 lb
Maximum load on cylinder 2 67995 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 1 days
Age of specimen in hours 24 hours