Print Report | Back to Test Summary

Testing Report for 2020-06-10-37-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 00000000
EFIS: 0000000000
Project ID: 9999
QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: RE_first RE_last
Structure Rep.: SR_First SR_Last

Sample Information

DIME Sample ID: 2020-06-10-37
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - DME / District Lab
Sample Organization Contact: (510) 507-3456
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 6/10/2020
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: 2 bags
A brief description of the sample: 1/2" RHMA-O
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hanson Sunol

Material Information

Source Identification (SMARA or name of Pit): 91-01-0011
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Hot Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number:
Lot number:
Sublot number:

Test Information

DIME Test ID: 2020-06-10-37-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Date Tested: 6/15/2020
Verified Date: 8/6/2020
Submitted By Organization: CT D04 - DME / District Lab
Organization Address: 21339 Cabot Blvd,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: mohammad.dehghan@dot.ca.gov
Organization Phone: (510) 507-3456
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified :

Submitted Test Results

What type of gradation is being tested?: Combined Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 95 %
Cumulative percent passing the 3/8 in. sieve: 80 %
Cumulative percent passing the #4 sieve: 28 %
Cumulative percent passing the #8 sieve: 13 %
Cumulative percent passing the #16 sieve: 8 %
Cumulative percent passing the #30 sieve: 6 %
Cumulative percent passing the #50 sieve: 5 %
Cumulative percent passing the #100 sieve: 3 %
Cumulative percent passing the #200 sieve: 1.9 %