Project Information

Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-01-14-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 01/14/2020
Date that the sample was received by the laboratory/organization performing the testing: 01/14/2020
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Sundance Fly Ash
From where was the sample collected: Source
Laboratory sample identification: CM205006
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: LaFarge

Material Information

Brand: LaFarge
Mill: Sundance
Type of Cementitious Material: Class F or N Flyash

Test Results

Test 1 of 3

DIME Test ID: 2020-01-14-4-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 08/18/2020
Date Tested: 07/27/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? yes
Age of specimen 7 days
The amount of flow 116 %
The amount of water used 47.2 %
Compressive strength of 1st specimen 3663 psi
Compressive strength of 2nd specimen 4013 psi
Compressive strength of 3rd specimen 4234 psi
Average Compressive strength (to nearest 10 psi) 4120 psi
Average Compressive strength (to nearest 10 psi) control group 4780 psi
Strength Activity Index of Portland Cement per ASTM C109 86 %

Test 2 of 3

DIME Test ID: 2020-01-14-4-3
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 08/18/2020
Date Tested: 08/17/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311? yes
Age of specimen 28 days
The amount of flow 116 %
The amount of water used 47.2 %
Compressive strength of 1st specimen 5210 psi
Compressive strength of 2nd specimen 4935 psi
Compressive strength of 3rd specimen 5577 psi
Average Compressive strength (to nearest 10 psi) 5070 psi
Average Compressive strength (to nearest 10 psi) control group 6060 psi
Strength Activity Index of Portland Cement per ASTM C109 84 %

Test 3 of 3

DIME Test ID: 2020-01-14-4-4
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 08/18/2020
Date Tested: 01/29/2020
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Correction Factor (CF) 0.30
Corrected Residue (Rc) 24.99