Print Report | Back to Test Summary

Testing Report for 2020-06-25-32-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 120R5404
EFIS: 1218000113
Project ID: 214625
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-1.6/33.1
Work Description: Methacrylate deck seal treatment and polyester concrete overlay
Location Description: FOR CONSTRUCTION ON STATE HIGHWAY IN ORANGE COUNTY AT VARIOUS LOCATIONS FROM EL CAMINO REAL UNDERCROSSING TO MAIN STREET OVERCROSSING
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Arsalan Naderi
Structure Rep.: Kugan Ramanathan

Sample Information

DIME Sample ID: 2020-06-25-32
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM2 - Type B Elastomeric Joint Seal
Sample Taken Date: 6/25/2020
Date that the sample was received by the laboratory/organization performing the testing: 6/30/2020
The quantity of what the sample constitutes: 550 ft
A brief description of the sample: 3.75 elastomeric joint seal
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Watson Bowman

Material Information

Mfg. Lot Number(s): 2320267
Manufacturer(s): Watson Bowman
Temperature: 72
Humidity: 50
Comments:
Joint Seal Size: 3.75"

Test Information

DIME Test ID: 2020-06-25-32-3
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Date Tested: 7/15/2020
Verified Date: 7/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

UTM: 2kip
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.069
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2054.33
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.068
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 2288.32
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.071
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2096.19
Sample 3 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2096.2 psi