Print Report | Back to Test Summary

Testing Report for 2020-06-30-7-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080C2514
EFIS: 0816000076
Project ID: 212112
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Matt Antonelli
Structure Rep.: Faisal Zahlout

Sample Information

DIME Sample ID: 2020-06-30-7
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 6/30/2020
Date that the sample was received by the laboratory/organization performing the testing: 6/30/2020
The quantity of what the sample constitutes: PSUE 2 Bags Agg. 1 Bag Rap
A brief description of the sample: 3/4" HMA-A-SP-R15 0.50% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0398A-20
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan-Corona Drum

Material Information

Source Identification (SMARA or name of Pit): 91-33-0027
The fabricator's/manufacturer's product name for the sample: 3/4 HMA-A-SP R15
The fabricator/manufacturer designation for the sample: Unknown
The plant number: 224112 CORD SJR
A detailed description of where the material sample was collected: Belt Cut at Vulcan Corona Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown

Test Information

DIME Test ID: 2020-06-30-7-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Date Tested: 7/2/2020
Verified Date: 7/7/2020
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test: Combined Virgin Aggregate Gradation
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

What type of gradation is being tested?: Combined Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 98 %
Cumulative percent passing the 1/2 in. sieve: 85 %
Cumulative percent passing the 3/8 in. sieve: 74 %
Cumulative percent passing the #4 sieve: 52 %
Cumulative percent passing the #8 sieve: 37 %
Cumulative percent passing the #16 sieve: 26 %
Cumulative percent passing the #30 sieve: 16 %
Cumulative percent passing the #50 sieve: 10 %
Cumulative percent passing the #100 sieve: 6 %
Cumulative percent passing the #200 sieve: 4.2 %