Print Report | Back to Test Summary

Testing Report for 2020-04-20-29-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 020J1604
EFIS:
Project ID: 214589
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-284-0.0/8.3
Work Description: PLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING).
Location Description: PLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer:
Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-04-20-29
TL Number from the TL Form: 733181
Sample Submitted By Organization: CT D02 - North Region Materials Lab
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 4/20/2020
Date that the sample was received by the laboratory/organization performing the testing: 4/21/2020
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: Combined 1/2-inch Type A Untreated Virgin Aggregate
From where was the sample collected: Source
Laboratory sample identification: D78406F
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Ward Lake Pit

Material Information

Source Identification (SMARA or name of Pit): 91-18-0008
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: Lab-Batched from Sized Untreated Aggregate Stockpiles
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number: JMF 20-04-S1
Lot number: Unknown
Sublot number: Unknown

Test Information

DIME Test ID: 2020-04-20-29-5
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Date Tested: 6/16/2020
Verified Date: 6/18/2020
Submitted By Organization: CT D02 - North Region Materials Lab
Organization Address: 1657 Riverside Dr,MS-83
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: (530) 225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Bulk specific gravity: 2.489
Bulk specific gravity (SSD Basis): 2.580
Apparent specific gravity: 2.738
Absorption: 3.6 %