Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2018-12-06-6
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 12/06/2018
Date that the sample was received by the laboratory/organization performing the testing: 12/06/2018
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: 4 Corners Fly Ash
From where was the sample collected: Source
Laboratory sample identification: CM195910
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SRMG
DIME Test ID: 2018-12-06-6-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 01/08/2021
Date Tested: 03/19/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 day test
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
yes
|
Age of specimen
|
7 days
|
The amount of flow
|
129 %
|
The amount of water used
|
48.4 %
|
Compressive strength of 1st specimen
|
3403 psi
|
Compressive strength of 2nd specimen
|
3491 psi
|
Compressive strength of 3rd specimen
|
3548 psi
|
Average Compressive strength (to nearest 10 psi)
|
3480 psi
|
Average Compressive strength (to nearest 10 psi) control group
|
4150 psi
|
Strength Activity Index of Portland Cement per ASTM C109
|
84 %
|
DIME Test ID: 2018-12-06-6-3
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 01/08/2021
Date Tested: 04/09/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 day test
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
yes
|
Age of specimen
|
28 days
|
The amount of flow
|
129 %
|
The amount of water used
|
48.4 %
|
Compressive strength of 1st specimen
|
4631 psi
|
Compressive strength of 2nd specimen
|
4681 psi
|
Compressive strength of 3rd specimen
|
4631 psi
|
Average Compressive strength (to nearest 10 psi)
|
4650 psi
|
Average Compressive strength (to nearest 10 psi) control group
|
5620 psi
|
Strength Activity Index of Portland Cement per ASTM C109
|
83 %
|
DIME Test ID: 2018-12-06-6-4
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 01/08/2021
Date Tested: 12/18/2018
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Correction Factor (CF)
|
0.30 %
|
Corrected Residue (Rc)
|
22.07 %
|