Print Report | Back to Sample Detail

Sample Record for 2020-04-23-20

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214591 DEA: 051M2704 EFIS: 0519000089 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-150-0.0/2.2
Work Description: RHMA OVERLAY, FULL WIDTH SEGMENT CORRECTION AND COLD PLANE AC.
Location Description: SANTA BARBARA COUNTY IN AND NEAR CARPINTERIA FROM ROUTE 101/150 SEPARATION TO VENTURA COUNTY LINE
Contractor Name: TORO ENTERPRISES INC
Contractor Address: P O BOX 6285, OXNARD CA 93030
Resident Engineer: Michael Mortensen Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-04-23-20
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Verification
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 04/23/2020
Date that the sample was received by the laboratory/organization performing the testing: 05/07/2020
The quantity of what the sample constitutes: One JMF Verification
A brief description of the sample: bag of RAP
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Saticoy

Material Information

RAP Source: Vulcan Saticoy
Aggregate Size: Unknown
Aggregate Source: Unknown
RAP Stockpile:
Stockpile Size (tons): Unknown
Reclaimed Asphalt Pavement Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2020-04-23-20-1
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 05/22/2020
Date Tested: 05/07/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 82.8 %
Cumulative percent passing the 3/8 in. sieve 58.6 %
Cumulative percent passing the 1/4 in. sieve 0 %
Cumulative percent passing the #4 sieve 30.5 %
Cumulative percent passing the #8 sieve 22.8 %
Cumulative percent passing the #16 sieve 18.6 %
Cumulative percent passing the #30 sieve 15 %
Cumulative percent passing the #50 sieve 11.2 %
Cumulative percent passing the #100 sieve 6.7 %
Cumulative percent passing the #200 sieve 4.5 %

Test 2 of 3

DIME Test ID: 2020-04-23-20-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/22/2020
Date Tested: 05/07/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 3.89 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test 3 of 3

DIME Test ID: 2020-04-23-20-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/22/2020
Date Tested: 03/20/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.535
Theoretical maximum density at 25°C (77°F) no data