Testing Report for 2020-05-21-7-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 024F2104
EFIS: 0212000072
Project ID: 213569
QA Service Level: 1
DIST-CO-RTE-PM: 02-MOD-299-0.5/1.0
Work Description: Butte and Ash Creek Bridge Replacement
Location Description: Construction of Butte Creek Bridge and Ash Creek Bridge on Route 299 at Adin
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mike Zdenek
Structure Rep.: Ryan G Duran

Sample Information

DIME Sample ID: 2020-05-21-7
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Sacramento Field Laboratory
Sample Organization Contact: (916) 227-7263
Type of Sample: Acceptance
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 5/21/2020
Date that the sample was received by the laboratory/organization performing the testing: 5/22/2020
The quantity of what the sample constitutes: 17
A brief description of the sample: #4 Button Heads
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Camblin

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 1064317
Head Manufacturer Lot Number(s): A163671
Rebar Size: #4
Headed Bar Model Name: BNX
Size of Head: Full Size - 9x
Head Connection Type: Crimped Head
Head Shape: Circular
Rebar Manufacturer: CMC
Head Manufacturer: Barsplice
Head Fabricator: Barsplice BNX Buttonheads
Material Standard Code: ASTM A706

Test Information

DIME Test ID: 2020-05-21-7-3
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Date Tested: 5/22/2020
Verified Date: 5/22/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: OK Necking
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Number of Headed Bar Samples: 1
Lot # Area (sqin) Peak Load (lbf) Tensile Strength (psi) Comments Tested By
1 0.2 20549 102744 OK Necking fsaylor
Temperature: 72 f
UTM: 400kip