Print Report | Back to Test Summary

Testing Report for 2020-04-24-2-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: 080J0704
EFIS: 0800000282
Project ID: 209694
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-215-0.6/1.7
Work Description: (Alternative Delivery) The CMGC project will reconstruct and improve interchange of I-215 and Barton Road in the City of Grand Terrace, CA.
Location Description: Grade separation at Intersection of I-215 and Barton Road near Grand Terrace, CA. ? On I-215 between I-10 and SR-60.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Fereydoon Alipanah
Structure Rep.: Tim Flores

Sample Information

DIME Sample ID: 2020-04-24-2
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 4/24/2020
Date that the sample was received by the laboratory/organization performing the testing: 4/27/2020
The quantity of what the sample constitutes: PSUE 6 Bags
A brief description of the sample: 3/4 HMA-A-SP R15 Aggregates and RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: 0201A-20
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Corona

Material Information

Source Identification (SMARA or name of Pit): 91-33-0027, 91-33-0073
The fabricator's/manufacturer's product name for the sample: 3/4 HMA-A-SP R15
The fabricator/manufacturer designation for the sample: Unknown
The plant number: 224112 CORD SJR
A detailed description of where the material sample was collected: Belt Cut at Vulcan Corona Plant
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown

Test Information

DIME Test ID: 2020-04-24-2-7
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Date Tested: 4/29/2020
Verified Date: 5/6/2020
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified :

Submitted Test Results

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Weighted percentage of particles (by mass) that were flat and elongated: 1 %
Weighted percentage of particles (by mass) that were not flat and elongated: 99 %