Print Report | Back to Sample Detail

Sample Record for 2020-03-23-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213733 DEA: 051C85U4 EFIS: 0518000156 QA Service Level: 1
DIST-CO-RTE-PM: 05-SCR-1-10.2/17.5
Work Description: Santa Cruz 1 CAPM and Bridge Rails
Location Description: SANTA CRUZ COUNTY IN AND NEAR SANTA CRUZ FROM NORTH APTOS UNDERPASS TO JUNCTION ROUTE 9.
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 585 West Beach Street, Watsonville, CA 95076
Resident Engineer: Gareth Gill Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-03-23-11
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 03/23/2020
Date that the sample was received by the laboratory/organization performing the testing: 04/17/2020
The quantity of what the sample constitutes: One JMF Renewal
A brief description of the sample: bags of aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Felton

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-44-0003::FELTON QUARRY
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: At the Plant
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:

Test Results

Test 1 of 7

DIME Test ID: 2020-03-23-11-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 05/01/2020
Date Tested: 04/22/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 92.6 %
Cumulative percent passing the 3/8 in. sieve 75.2 %
Cumulative percent passing the #4 sieve 51.9 %
Cumulative percent passing the #8 sieve 40 %
Cumulative percent passing the #16 sieve 27.3 %
Cumulative percent passing the #30 sieve 18.1 %
Cumulative percent passing the #50 sieve 10.5 %
Cumulative percent passing the #100 sieve 4.4 %
Cumulative percent passing the #200 sieve 2.2 %

Test 2 of 7

DIME Test ID: 2020-03-23-11-2
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 05/01/2020
Date Tested: 04/23/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.594
Absorption 0.6 %

Test 3 of 7

DIME Test ID: 2020-03-23-11-3
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 05/01/2020
Date Tested: 04/23/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity 2.598
Bulk specific gravity (SSD Basis) 2.610
Apparent specific gravity 2.631
Absorption 0.5 %

Test 4 of 7

DIME Test ID: 2020-03-23-11-4
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 05/01/2020
Date Tested: 04/20/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced and Fine 1 Faced
Percentage of fractured, coarse, 2 faced particles tested 98 %
Percentage of fractured, coarse, 1 faced particles tested 99 %
Percentage of fractured, fine, 1 faced particles tested 97 %

Test 5 of 7

DIME Test ID: 2020-03-23-11-5
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 05/01/2020
Date Tested: 03/04/2019
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation B
Percent loss after 100 revolutions 8 %
Percent loss after 500 revolutions 35 %

Test 6 of 7

DIME Test ID: 2020-03-23-11-6
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 05/01/2020
Date Tested: 04/21/2020
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 82

Test 7 of 7

DIME Test ID: 2020-03-23-11-7
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 05/01/2020
Date Tested: 03/04/2019
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method A
Determination By Mass
Dimensional ratio used 5:1
Weighted percentage of particles (by mass) that were flat 0 %
Weighted percentage of particles (by mass) that were elongated 0 %
Weighted percentage of particles (by mass) that were both flat and elongated 0 %