Print Report | Back to Sample Detail

Sample Record for 2020-03-24-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214421 DEA: 01362704 EFIS: 0116000031 QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-1-62.2/R78.9
Work Description: HOT MIX ASPHALT OVERLAY.
Location Description: MENDOCINO COUNTY NEAR FORT BRAGG FROM 0.1 MILE NORTH OF PUDDING CREEK BRIDGE TO 0.6 MILE NORTH OF WAGES CREEK BRIDGE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 1324 South State Street, Ukiah, CA 95482
Resident Engineer: Roozbeh Hadipour Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-03-24-8
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 03/24/2020
Date that the sample was received by the laboratory/organization performing the testing: 04/10/2020
The quantity of what the sample constitutes: 200 pieces
A brief description of the sample: ASTM A193 B7 Stud
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: BAY STANARD MANUFACTURING

Material Information

Rocap Number(s): N/A
Heat Number(s): 10599080
Nut Mfg. Lot Number(s): N/A
Washer Mfg. Lot Number(s): N/A
Bolt Specification: ASTM A193 B7
Bolt Length(s): 18"
Nut Specification: N/A
Washer Specification: N/A
Finish: ASTM A153 HDG
Diameter/Size: 3/4"
Bolt Mfg. Lot Number: 2002171A-4
Rocap Test Requirement(s): NO
Lubricant Requirements(s): NO

Test Results

Test 1 of 18

DIME Test ID: 2020-03-24-8-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 B7 Stud
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1UNC 3/4 0.3344599020413766900A193 B7 Stud
UTM 400kip
Temperature 72

Test 2 of 18

DIME Test ID: 2020-03-24-8-2
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 B7 Stud
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
2UNC 3/4 0.3344588120413736712778242679A193 B7 Stud
UTM 400kip
Temperature 72

Test 3 of 18

DIME Test ID: 2020-03-24-8-3
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 B7 Stud
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
3UNC 3/4 0.3344619820513830912855042936A193 B7 Stud
UTM 400kip
Temperature 72

Test 4 of 18

DIME Test ID: 2020-03-24-8-4
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 B7 Stud
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
4UNC 3/4 0.3344620920513833612726542506A193 B7 Stud
UTM 400kip
Temperature 72

Test 5 of 18

DIME Test ID: 2020-03-24-8-5
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 B7 Stud
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
5UNC 3/4 0.3344569020313678312807942779A193 B7 Stud
UTM 400kip
Temperature 72

Test 6 of 18

DIME Test ID: 2020-03-24-8-6
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 B7 Stud
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
6UNC 3/4 0.3344598420413765712792942728A193 B7 Stud
UTM 400kip
Temperature 72

Test 7 of 18

DIME Test ID: 2020-03-24-8-7
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 B7 Stud
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
7UNC 3/4 0.3344588320413737412789942718A193 B7 Stud
UTM 400kip
Temperature 72

Test 8 of 18

DIME Test ID: 2020-03-24-8-8
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 B7 Stud
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
8UNC 3/4 0.3344606220413786312894443067A193 B7 Stud
UTM 400kip
Temperature 72

Test 9 of 18

DIME Test ID: 2020-03-24-8-9
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A193 B7 Stud
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
9UNC 3/4 0.3344641220613894112900443087A193 B7 Stud
UTM 400kip
Temperature 72

Test 10 of 18

DIME Test ID: 2020-03-24-8-10
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 10599080
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .75 in
Bolt Length 18 in
Pitch Diameter .696 in
Pitch Diameter 2nd no data in

Test 11 of 18

DIME Test ID: 2020-03-24-8-11
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 10599080
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .75 in
Bolt Length 18 in
Pitch Diameter .690 in
Pitch Diameter 2nd no data in

Test 12 of 18

DIME Test ID: 2020-03-24-8-12
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 10599080
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .75 in
Bolt Length 18 in
Pitch Diameter .691 in
Pitch Diameter 2nd no data in

Test 13 of 18

DIME Test ID: 2020-03-24-8-13
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) 10599080
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .75 in
Bolt Length 18 in
Pitch Diameter .692 in
Pitch Diameter 2nd no data in

Test 14 of 18

DIME Test ID: 2020-03-24-8-14
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) 10599080
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .75 in
Bolt Length 18 in
Pitch Diameter .690 in
Pitch Diameter 2nd no data in

Test 15 of 18

DIME Test ID: 2020-03-24-8-15
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1F
Rocap Number no data
Heat Number(s) 10599080
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .75 in
Bolt Length 18 in
Pitch Diameter .687 in
Pitch Diameter 2nd no data in

Test 16 of 18

DIME Test ID: 2020-03-24-8-16
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1G
Rocap Number no data
Heat Number(s) 10599080
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .75 in
Bolt Length 18 in
Pitch Diameter .687 in
Pitch Diameter 2nd no data in

Test 17 of 18

DIME Test ID: 2020-03-24-8-17
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1H
Rocap Number no data
Heat Number(s) 10599080
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .75 in
Bolt Length 18 in
Pitch Diameter .688 in
Pitch Diameter 2nd no data in

Test 18 of 18

DIME Test ID: 2020-03-24-8-18
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 04/15/2020
Date Tested: 04/15/2020
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1I
Rocap Number no data
Heat Number(s) 10599080
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings PURPLE PAINT
Size .75 in
Bolt Length 18 in
Pitch Diameter .690 in
Pitch Diameter 2nd no data in